Njengemishini yamandla eyinhloko ekukhiqizeni izimboni, ama-air compressor akhiqiza ukushisa okukhulu ngesikhathi sokusebenza. Uma ukushisa kungakwazi ukuchithwa ngesikhathi nangendlela ephumelelayo, kuzoholela ekunciphiseni ukusebenza kahle kweyunithi, ukwanda kokusetshenziswa kwamandla, ngisho nempilo yesevisi yemishini ibe mfushane.

 

 

Njengesisetshenziswa esiyisihluthulelo esisekelayo sokupholisa i-compressor yomoya, impahla yekhoyili ye uvaliwe{0}umbhoshongo wokupholisa oyisekhethi inquma ngokuqondile ukusebenza kahle kokushintshanisa ukushisa, impilo yesevisi kanye nezindleko zokusebenza, ngakho ukukhetha okunengqondo kubaluleke kakhulu.

 

Kuhlanganiswe nezici zokusebenza zama-compressor komoya (izinga lokushisa eliphumayo elingu-80-95 degree, indawo ejikelezayo iningi lamanzi asezimbonini noma i-antifreeze), izinto ezisetshenziswayo zamanje zamakhoyili ngokuyinhloko zihlanganisa ithusi, 304/316L insimbi engagqwali, nensimbi ye-carbon galvanized. Ingxubevange ye-Titanium ingasetshenziswa ezindaweni ezigqwalile kakhulu. Izinto ezisetshenziswayo ezihlukene zinomehluko ekusebenzeni, izimo ezisebenzayo kanye nezindleko, futhi zidinga ukukhethwa ngokwesayensi ngokuya ngezidingo zangempela.

481.jpg

 

 

Incazelo Yemikhiqizo

 

 

 

Amakhoyili ethusi ayizinto ezikhethwayo eziphezulu-ezisebenza kahle kakhulu-zemibhoshongo yokupholisa eyiziyingi{1}ezipholile zokupholisa i-air compressor, egqamayo ngenxa ye-thermal conductivity enhle kakhulu. I-thermal conductivity yayo ingafinyelela ku-380W/m·k, okuyisilinganiso esiphindwe izikhathi ezingu-20 kuneyensimbi engagqwali.

 

460.jpg

 

 

Ingakwazi ukuphatha ngokushesha izinga lokushisa eliphezulu-eliphezulu okukhiqizwa i-air compressor ukuze kufinyelele ukupholisa okuphumelelayo, ikakhulukazi ezifanele izidingo zokupholisa{1}}zama-air compressor aphezulu afana nezikulufu nezinhlobo ezimaphakathi. Ngesikhathi esifanayo, ithusi ngokwemvelo linokumelana okuhle kwamanzi kanye nokumelana nokugqwala kwe-asidi ebuthakathaka, nobuchwepheshe bokushisela obuvuthiwe nokuvaleka okuqinile.

 

455.jpg

Ngaphansi kokugcinwa okujwayelekile, impilo yayo yesevisi ingafinyelela eminyakeni engaphezu kwengu-20. Kodwa-ke, izinto zethusi nazo zineziphambeko ezisobala: intengo yayo iphakeme kakhulu, cishe izikhathi ezingu-1.5 kunensimbi evamile engagqwali, futhi ubuso bayo bujwayele ukukala, obudinga ukuhlanzwa nokugcinwa njalo.

 

Ukwengeza, ikhono layo lokumelana ne-ammonia, ama-sulfide kanye ne-ion ye-chloride ephezulu (i-concentration engaphezu kuka-200mg/L) ibuthaka, ngakho-ke ayizifanele lezi zimo ezonakalisayo.Amakhoyili ethusi afaneleka kakhulueziteshini ze-compressor zomoya ezimaphakathi nezinkulu ezinezidingo eziphezulu zokusebenza kahle kokushintshanisa ukushisa, ikhwalithi yamanzi ahlanzekile nesabelomali esanele, njengokukhiqiza ukunemba, izikhungo zedatha nezinye izimboni ezinezidingo eziphakeme kakhulu zokuzinza kokusebenza kwemishini.

 

 

Incazelo Yemikhiqizo

 

 

 

Amakhoyili ensimbi engagqwali angu-304/316L ayizinto zamanje eziqinile eziqinile-zemibhoshongo epholisa umoya eyindilinga yokupholisa i-compressor yomoya, ukusebenza kokulinganisa kanye nomnotho, futhi ifanele izimo eziningi zezimboni. Phakathi kwazo, i-thermal conductivity yamakhoyili ensimbi engagqwali angu-304 imayelana ne-16W/m·k.

 

46.jpg

 

Nakuba ingeyinhle njengekhopha, inokumelana nokugqwala okuhle kokungathathi hlangothi futhi okubuthakathaka, nomfutho-nomthamo wokuthwala ongaphezu kuka-1.6MPa. Ubuso bayo bushelelezi futhi akulula ukukala, ngezindleko eziphansi zokunakekela kanye nempilo yesevisi yeminyaka eyi-15-20. Intengo yayo iphakathi, okwenza kube ukukhetha okujwayelekile kwezindawo ezijwayelekile zezimboni.

 

 

 

Closed Cooling Tower For Reaction KettleIfanele izimo zokusebenza ezivamile nge-chloride ion concentration engaphansi kuka-200mg/L, njengezinhlelo ze-compressor zomoya ezimayini, izinto zokwakha kanye nezimboni ezijwayelekile zokukhiqiza.

 

Ngokwesisekelo sezinto ezingama-304, amakhoyili ensimbi engagqwali angu-316L engeza isici se-molybdenum, esithuthukisa kakhulu ukumelana nokugqwala kwe-pitting kanye nokugqwala kwe-chloride.

 

Ingakwazi ukuzivumelanisa nezimo ezigqwala kakhulu njengesifutho sikasawoti omningi ogwini kanye nemboni yamakhemikhali, nempilo yesevisi engaphezu kweminyaka engama-20. Intengo yayo ingu-20% -30% ephakeme kunaleyo yensimbi engagqwali engu-304, ifanele izimo ezinezidingo eziphakeme zokuqina kwemishini kanye nokugqwala okuqinile kwemvelo.

 

 

Incazelo Yemikhiqizo

 

 

 

Winter Maintenance and Upkeep of Closed Cooling TowersAmakhoyili ensimbi ye-galvanized carbon ayizinto eziyisisekelo zezomnotho, ezilungele kakhulu izimo ezinesabelomali esiphansi kakhulu kanye nokusetshenziswa kwesikhashana. Inzuzo yayo enkulu yintengo ephansi, cishe i-1/3 kuphela yamakhoyili ethusi, enamandla amakhulu emishini kanye nobuchwepheshe obulula bokucubungula, obungakwazi ukuhlangabezana nezidingo eziyisisekelo zokupholisa zama-compressor amancane.

 

Kodwa-ke, le nto inokumelana nokugqwala okungekuhle, incike kakhulu kungqimba olungaphezulu lwamagalani ukuze ivikeleke. Uma ungqimba olufakwe uthayela lonakalisiwe, ipayipi lijwayele ukugqwala nokubhobozwa, impilo yesevisi yeminyaka engu-3-5 kuphela kanye nezindleko eziphezulu zokulungisa ezilandelayo.

 

 

Ngakho-ke, amakhoyili ensimbi ye-galvanized carbon afaneleka kuphelaama-compressor amancane angaphansi kuka-50kW,amaphrojekthi-esikhathi esifushane noma izimo zokupholisa zesikhashana ezinekhwalithi yamanzi enhle kakhulu, futhi azinconyelwe{1}}ukusetshenziswa kwesikhathi eside kumasistimu okupholisa ama-compressor emoyeni ekukhiqizeni kwezimboni.

 

 

Incazelo Yemikhiqizo

 

 

 

Amakhoyili e-Titanium alloy asetshenziswa kakhulu ezindaweni ezigqwala kakhulu futhi ayizinto ezikhethwayo ezimweni ezikhethekile zokusebenza. Inokumelana nokugqwala okuqinile, ingamelana nokuguguleka kwezindawo ezimbi kakhulu njengama-asidi aqinile, ama-alkali aqinile namanzi olwandle (i-chloride ion concentration engaphezu kuka-20000mg/L), enomoya oshisayo omaphakathi kanye nempilo yesevisi engaphezu kweminyaka engu-30, engaqinisekisa{3}}ukusebenza okuzinzile kwesikhathi eside kwama-compressor omoya endaweni enzima.

TOP 10 Counterflow Closed-circuit Cooling Tower manufacturer India 2026

 

Kodwa-ke, i-titanium alloy material ibiza kakhulu, futhi ibiza kakhulu kunezinye izinto. Isetshenziswa kuphela ezinhlelweni ezinkulu ze-compressor air ezimweni ezigqwala kakhulu njengesifutho sikasawoti ogwini kanye negesi yemfucuza yamakhemikhali, futhi ayidingeki ezimweni ezijwayelekile zezimboni.

 

 

Incazelo Yemikhiqizo

 

 

 

Kafushane, ukukhethwa kwento yekhoyili yemibhoshongo evaliwe- yokupholisa isekethe yokupholisa i-air compressor ikakhulukazi ukulinganisa ukusebenza kahle kokushintshisana kokushisa, ukumelana nokugqwala kanye nezindleko zokusebenza.

 

 

Winter Anti-Freezing Measures For Closed-Circuit Cooling Towers

Kuma-compressor omoya aphakathi nendawo amakhulu, izimo ezinezidingo zokushintshaniswa kokushisa okuphezulu kanye nesabelomali esanele, amakhoyili ethusi ayakhethwa; ngezimo eziningi ezijwayelekile zezimboni,304/316L amakhoyili ensimbi engagqwaliziyizinqumo ezingcono kakhulu zokulinganisa ukuqina nomnotho; amakhoyili ensimbi ekhabhoni angasetshenziselwa amaphrojekthi amancane wesikhashana ukulawula izindleko; amakhoyili e-titanium alloy ayadingeka ezindaweni ezigqwalile kakhulu.

 

 

 

Ekukhetheni kwangempela, kuyadingeka futhi ukucubungulisisa izici ezifana nekhwalithi yamanzi, amandla eyunithi nokugqwala kwemvelo, ukubeka phambili ekuqinisekiseni ukusebenza{0}}okuzinzile kwesikhathi eside kwemishini, nokunciphisa izindleko zokunakekela ngesikhathi esifanayo, ukuze kufinyelelwe ukumetanisa okuphumelelayo phakathi kwama-compressor omoya kanye{1}}nemibhoshongo yokupholisa eyindilinga evaliwe.

 

 