I-TDS isifinyezo se-Total Dissolved Solids, esisho isamba sengqikithi yazo zonke izinto ezingaphili ezincibilikayo nezincibilika emanzini, zikalwa ngo-mg/L noma ppm.

Embhoshongweni opholisa amanzi ajikelezayo, i-TDS ikakhulukazi iqukethe i-calcium ion, ion magnesium, ion chloride, ion sulfate, silicate kanyeamanye amaminerali kasawoti, kanye nezingcolisi eziphilayo ezincibilikisiwe ezilethwa uthuli lomoya kanye negesi ye-industrial flue.

 
1396

amalungu asebenzayo

 
15+

isipiliyoni seminyaka

 
125+

imicimbi nezinselelo

 
12

abafundisi abangongoti

 

Inani le-TDS liwumgogodla wokulawula izinga lamanzi lenkomba yokusebenza kombhoshongo wokupholisa, enquma ngokuqondile ukukalwa, ukugqwala kanye nezingozi zokuzala kabusha kwe-microbialamasistimu okupholisa acishe abe{{0}avaliwe, kanye nokuphathwa okungalungile kwe-TDS kuzodala izingozi ezinkulu ezifihliwe ekusebenzeni kahle kokupholisa kanye nempilo yesevisi yemishini.

 

 

What Coil Material to Use for Closed-Circuit Cooling Towers for Air Compressor Cooling?Indlela yokwakheka kwe-TDS ephezulu emanzini ombhoshongo wokupholisa ilele kumjikelezo wokugxilisana oqhubekayo wamanzi.

 

Imibhoshongo yokupholisa incike ekuhwamukeni kwamanzi ukuze isuse ukushisa, kuyilapho amanzi ahlanzekile ehwamuka abe emoyeni, futhi zonke izinto zamaminerali ezincibilikisiwe azikwazi ukuhwamuka futhi zihlale emanzini ajikelezayo ngokuqhubekayo.

 

Ngokulahleka kwamanzi okuqhubekayo, ukugcwala kwezinto ezincibilikayo kuyaqhubeka nokukhuphuka, futhiinani le-TDS likhuphuka ngokulandelana ngesikhathi sokusebenza.

 

Ngisho noma imboni igcwalisa amanzi kampompi ahlanzekile noma amanzi omthombo nsuku zonke, amanzi amasha azoletha izingxenye zamaminerali ezintsha, okuqhubekisele phambili ukusheshisa ukunqwabelana kwe-TDS.

 

 

Emibhoshongweni yokupholisa evulekile echayeke emkhathini, uthuli lwangaphandle, inkungu ye-asidi yezimboni, inkungu kasawoti kanye nokungcola okuphilayo kuzolokhu kuncibilika emanzini ajikelezayo, okuzoqhubeka nokukhuphuka.izinga le-TDS.

 

 

Do Closed Cooling Towers Need Frequent Water Replenishment During Operation?Ezimbonini ezingasogwini, ama-ion e-chloride enkungu kasawoti andisa kakhulu i-TDS; emapaki ezimayini namakhemikhali, ama-sulfate nezinsimbi ezisindayo ezincibilikisiwe kwenza i-TDS yeqe izinga ngokushesha.

 

Amasistimu okupholisa avaliwe anejubane eliphansi le-TDS elikhuphukayo ngoba ingaphakathi lihlukanisiwe nomoya, kodwa{0}}ukusebenza kwesikhathi eside kanye nokugcwaliswa kabusha kwamanzi okujwayelekile kusazoholela ekugxiliseni kancane kwe-TDS.

 

 

I-TDS ephezulu kakhulu iletha izingozi ezintathu ezinkulu ezibulalayo kumbhoshongo wokupholisa kanye nezinto ezisekelayo. Ingozi yokuqala ukukala okukhulu. I-calcium ne-magnesium usawoti yizici eziyinhloko ze-TDS. Uma i-TDS yeqa umkhawulo omisiwe, umkhawulo wokuncibilika kwe-calcium carbonate, i-magnesium silicate nezinye izimvula ziyaphuka, futhi isikali sekristalu sinamathela ngaphezu kwezishintshi zokushisa, amapayipi akhoyili namashubhu e-condenser.

 

 

Why Are Closed Circuit Cooling Towers So Popular?

Isikali sinokusebenza okushisayo okuphansi kakhulu, okunciphisa kakhulu ukusebenza kahle kokushintshaniswa kokushisa. Lapho ubukhulu besikali bufinyelela ku-0.3mm, amandla okukhipha ukushisa emishini yokupholisa ehla ngamaphesenti angaphezu kuka-20, okuholela ekushiseni ngokweqile kwemishini, ukuvalwa kokukhiqiza nokwenyuka kokusetshenziswa kwamandla kwamafeni namaphampu amanzi.

 

 

Ukukhetha okwenziwa ngesandla kanye nokwehliswa kwemishini kudinga isikhathi eside sokuphumula kanye nezindleko zokunakekela eziphezulu, kanyepickling njaloizocekela phansi izindonga zamapayipi ensimbi futhi ibangele izingozi zokuvuza ezifihliwe.

 

 

Ingozi yesibili ukugqwala kwensimbi okusheshisiwe. I-Chloride ne-sulfate ions ku-TDS ayimithombo eqinile edlayo. Amanzi ajikelezayo e-TDS aphezulu akha indawo yokugqwala kwe-electrochemical emapayipini ensimbi ye-carbon, amakhoyili ensimbi engagqwali nezimbotshana zokupompa.

 

 

 

Disadvantages Of Closed-Loop Cooling SystemsAma-ion e-chloride azongena kwifilimu yokwenziwa endaweni yensimbi, abangele ukugqwala komgodi kanye nokubhobozwa kwamakhoyili okushintshanisa ukushisa, ikakhulukazi insimbi engagqwali eyi-duplex namapayipi ethusi emibhoshongweni yokupholisa evaliwe.

 

Ezimweni ezimbi kakhulu, ukuvuza okumaphakathi okupholisa kuzongcolisa okokusebenza kokukhiqiza okufana nolayini bokukhiqiza amabhethri nama-reactors emithi. I-TDS ephezulu iphinde iqinise ukugqwala kwe-galvanic phakathi kwezinto ezihlukene zensimbi ohlelweni lwamapayipi, ifinyeze impilo yesevisi yama-valve,amaphampu ajikelezayokanye nezixhumi zokuxhuma ngesigamu noma ngaphezulu.

 

 

What Are the Disadvantages of Evaporative Cooling?Ingozi yesithathu ukuzalanisa okukhulu kwama-microorganisms kanye ne-biological slime.Ukugxila{0}okuphezuluokuqinile okuncibilikisiwe kuqukethe imisoco ecebile njenge-nitrogen ne-phosphorus, enikeza indawo efanelekile yokukhula kwamabhaktheriya, ulwelwe kanye nesikhunta.

 

Inani elikhulu le-biological slime linamathela odongeni lwangaphakathi lwamapayipi nama-filler, luvimbe iziteshi zokugeleza kwamanzi futhi lunciphise umthamo wokujikeleza kwamanzi okupholisa.

 

I-Biological slime futhi yakha isendlalelo esimbozayo endaweni yensimbi, lapho umehluko wokugcwala komoyampilo uzodala ukugqwala kwendawo ngaphansi kodaka. Ngasikhathi sinye, ama-microorganisms azobola izinto eziphilayo ukuze akhiqize izinto ezine-asidi, aqhubekisele phambili ukugqwala kwamapayipi futhi akhe umjikelezo ononya wokukala, i-slime kanye nokugqwala.

 

 

 

What is an evaporative condenser?

Ukusebenza kombhoshongo wokupholisa kuncike ekushayeni phansi ukuze ulawule i-TDS phakathi kwebanga eliphephile. Uhlobo ngalunye lwemishini yokupholisa lunezinga elimisiwe lokulawula i-TDS ngokuya ngempahla yamapayipi nesimo sokusebenza.

 

 

Imibhoshongo yokupholisa yensimbi evamile evulekile ngokuvamile ilawula i-TDS ngaphansi kuka-1000ppm; insimbi engagqwali amakhoyili okupholisa avaliwe adinga i-TDS engaphansi kuka-600ppm; i-coastal anti{2}}i-corrosion equipment ikhawulela i-TDS ngaphansi kuka-400ppm ukunciphisa okuqukethwe kwe-chloride.

 

Lapho umtshina we-TDS eku-inthanethi uthola ukuthi inani lenombolo lidlula izinga, i-valve yokushaya i-othomathikhi ivuleka ukuzekhipha{0}}amanzi angcolile aphezulu, kanye namanzi amasha aphansi-e-TDS enza-amanzi engezwa ukuze kuhlanjululwe amanzi ajikelezayo futhi kuncishiswe ukugcwala kwe-TDS kukonke.Ama-opharetha azophinde engeze ama-scale inhibitors, ama-corrosion inhibitor nama-biocides ukuze kwehlise isivinini izingozi ezibangelwa ukunqwabelana kwe-TDS, kodwa ama-ejenti amakhemikhali angakwazi ukubambezela ubungozi bokugxilisa ingqondo futhi awakwazi ukwehlisa i-TDS, ngakho-ke i-Blowdown evamile kuseyindlela yokulawula ewumongo.

Hydraulic Oil Cooling Tower

Ukulawulwa okungalungile kwe-TDS kuzophinde kwenyuse izindleko zokusebenza zokukhiqiza. Ukushaywa ngokweqile kokunciphisa i-TDS kuholela ekumoshweni okukhulu kwemithombo yamanzi, ukukhuphuka kwemali yokuhlanza amanzi nendle; ukushaya phansi okwanele kubangela ukwehluleka ukukala nokugqwala okwandayo, ukwandisa ukulungiswa, ukubuyisela kanye nokulahlekelwa kokuvala. Ngakho-ke,ukuqapha-kwesikhathi sangempela se-TDSkanye nokushaywa okuzenzakalelayo okulinganiselwe sekuphenduke ukumiswa okujwayelekile kwemibhoshongo yesimanje yokupholisa izimboni, ukulinganisa ukusetshenziswa kwamanzi nokuphepha kwemishini.

 

Hydraulic Oil Cooling Tower

 

Ukufingqa, i-TDS imele konke ukungcola kwamaminerali ancibilikisiwe emanzini okupholisa ajikelezayo. Ukugxila kwawo okuqhubekayo okubangelwa ukuhwamuka kwamanzi kuwumsuka wokukala, ukugqwala kanye nezinkinga ze-biological slime.

 

 

Desalinated Water Cooling Tower

 

Ukulawula ngokuqinile i-TDS ngaphakathi kwebanga lokuphepha lokuklama ngokusebenzisa i-blowdown kanye nokwelashwa kwamakhemikhali ekhwalithi yamanzi kuyisihluthulelo sokuzinza, ukusebenza kahle kanyeukusebenza-kwempilo ende kwezonke izinhlelo zokupholisa ezivulekile nezivaliwe. Ukunganaki ukuqapha kwe-TDS kuzoholela ekwehliseni ukusebenza kahle kokupholisa, ukulimala njalo kwemishini kanye nokulahlekelwa okukhulu kwezomnotho kwemigqa yokukhiqiza yezimboni.